Lakhta Center: Automated Structural and Geotechnical Health Monitoring
Lakhta Center: Automated Structural and Geotechnical Health Monitoring
DOI:
https://doi.org/10.22337/2077-9038-2018-4-94-108Keywords:
«Лахта Центр», СМДС, СМИК, система мониторинга конструкций, геотехнический мониторинг, программное обеспечение, мониторинг основания, высотное зданиеAbstract
"Lakhta Center" became a large scale public and office project in Primorskiy district of Saint-Petersburg, Russia. The Complex is comprised of supertall Tower, Multifunctional Building and the Arch with long span structures integrated with stylobate part. A number of innovation technologies and design solutions have been applied during the construction of the project.
According to the Building Codes and Regulations, to improve structural safety during the construction and maintenance periods, permanent structural health monitoring (SHM) program has been developed.
The main objective of SHM is to minimize structural failure risks due to uncertainties in soil and structural materials behavior.
General information about design and organizational arrangements for deploying automated structural and geotechnical health monitoring system of the "Lakhta Tower" is provided in the following paper. SHM architecture and topology, applied instrumentation, measurement methodology, software and monitoring parameters of the structure are described.
The article presents the results of the Tower structural behavior monitoring during the construction period. The correlation between the measured and the predicted Tower structure performance was analyzed and found in good agreement. A few anomalies were identified and investigated.
The focus is made to the informational value of the monitoring data for the increasing of soil, foundation and structure FE-modelling quality for construction accompaniment purposes.
References
Шулятьев, О.А. Основания и фундаменты высотных зданий / О.А. Шулятьев. - Москва: АСВ, 2016. - 391 с.
Contreras,I.A. The Use of the Fully-Grouted Method for Piezometer Installation / I.A. Contreras, A.T. Grosser, R.H. VerStrate // Proceedings of the 7th International Symposium on Field Measurements in Geomechanics. - Boston, MA: FMGM, 2007.
McRae, J.B. Long-term stability of vibrating wire instruments. One manufacturer's perspective / J.B. McRae, T. Simmonds // Proceedings of the 3th International Symposium on Field Measurements in Geomechanics. - Oslo, Norway: FMGM, 1991. - С. 283-293.
DiBiagio, E.A. Case study of Vibrating-Wire Sensors That Have Vibrated Continuously For 27 Years / E.A DiBiagio // Proceedings of the 6th International Symposium on Field Measurements in Geomechanics. -Oslo, Norway, 2003.
Sorum, G. Vibrating-wire reinforcement strain gauges for performance monitoring oflarge concrete structures / G. Sorum, T. Dyken // IABSE reports. - Norway, 1987.
Экспериментальные исследования сталежелезобетонных конструкций, работающих на внецентренное сжатие / В.И. Травуш, Д.В. Конин, Л.С. Рожко [и др.] //Academia. Архитектура и строительство. - 2016. - № 3. - С. 127-135.
СП 63.13330.2012. Бетонные и железобетонные конструкции. Основные положения / Введ. 2013-01-01. - М., 2013.
Abdelrazaq, A. Validating the Structural Behavior and Response of Burj Khalifa: Synopsis of the Full-Scale Structural Health Monitoring Programs / A. Abdelrazaq // International Journal of High-Rise Buildings. - 2012. - Т. 1. - № 1.